Industrial and utility segment · Poland
BESS Energy Storage from 1 MWh to 1000 MWh
Short answer
We deliver containerised energy storage systems ranging from 1 MWh to over 1000 MWh. Base block: 1 MW power / 2 MWh capacity in a liquid-cooled 20 ft container with LFP cells. Modular configuration lets you scale the installation without changing the system architecture.
1–1000+
MWh — supported capacity range
6.9
MWh max. in a single 20 ft container
86–89%
AC round-trip efficiency at 0.5C
10 years
capacity guarantee at 70% SOH
Main site axis
What project scale are you interested in?
You are not choosing a model — you are choosing a scale. We match container configuration, power and C-rate to the MWh you need.
1–3 MWh
manufacturing plants, EV charging stations, 0.5–2 MW PV farms
1 × 20ft container · 0.5–1.5 MW · 0.5C (2h) or 0.25C (4h)
3–10 MWh
2–5 MW PV farms, large industrial plants
2–3 × 20ft containers · 1.25–2.5 MW · 0.5C standard, 0.25C for shifting PV output
10–50 MWh
IPPs, grid-scale projects, capacity market auction participants
4–8 × 20ft containers · 5–25 MW · 0.5C for the capacity market, 0.25C for ancillary services
50–200 MWh
IPP developers, infrastructure funds
16–20 × 20ft containers · 25–50 MW · 0.25C (4h) most commonly, 0.5C for a capacity profile
200–1000+ MWh
utilities, public tenders, infrastructure fund portfolios
150–200 × 20ft containers in 50 MWh blocks · 125–250 MW · 0.25C (4h), optionally 0.125C (8h)
Not sure how many MWh you need?
Power and capacity sizing guide
MW vs. MWh, C-rate, 2h and 4h configurations, price ranges, permitting.
Architecture
Base block: 1 MW / 2 MWh in a 20 ft container
Every project, regardless of scale, is built from the same repeatable blocks. This means scaling up never requires redesigning the system.
20 ft container
6.06 × 2.44 m, weight 30–38 t, 5.0–6.9 MWh per unit. Transport without oversize permits.
Liquid cooling
Cell operating window of 15–35°C regardless of weather. Own consumption of 1.5–2.5% of throughput energy.
LFP cells
CATL, EVE Energy, Hithium, BYD. 8,000–11,000 cycles, 10–12-year guarantee at 70% SOH.
PCS and EMS
1.25–2.5 MW PCS at 98.3–98.8% efficiency, EMS integrated with SCADA and the balancing market.
Intent silo
Applications
The same architecture, a different revenue model. Choose the scenario that fits your asset.
2–40 MWh
Solar Farm
No more negative prices and curtailment — shift production to the evening peak.
1–10 MWh
Manufacturing Plant
Peak shaving and capacity-fee reduction for contracted capacity of 1–10 MW.
10–100 MWh
Capacity Market
A standby capacity agreement for a storage unit in a 2h configuration.
10–200 MWh
Ancillary Services and DSR
aFRR, mFRR and demand-side response (DSR) as a second revenue stream from the same installation.
1–3 MWh
EV Charging Station
A 300 kW charger on a 100 kW connection without grid expansion.
1–20 MWh
Limited Grid Connection
Storage instead of connection upgrades — faster and cheaper than new connection terms.
5–100 MWh
Wind Farm
Smoothing the production profile and operating within a limited connection point.
5–50 MWh
Data Center
Backup power and arbitrage from a single asset.
Numbers, not adjectives
LFP cells: CATL, EVE Energy, Hithium, BYD
The cell manufacturer matters more than the logo on the container. Our quotes always specify the exact model and cell capacity.
| Manufacturer | Model | Cell capacity | Cycles | Warranty |
|---|---|---|---|---|
| CATL | EnerC / EnerOne | 306 / 314 Ah | 8,000–10,000 | 10 years / 70% SOH |
| EVE Energy | LF628 | 628 Ah | 10,000 | 10 years / 70% SOH |
| Hithium | MIC 1130 | 1,130 Ah | 11,000 | 12 years / 70% SOH |
| BYD | Blade 2 | 710 Ah | 10,000 | 10 years / 70% SOH |
| REPT Battero | Wending 320 | 320 Ah | 8,000 | 10 years / 70% SOH |
| CALB | L500 | 587 Ah | 10,000 | 10 years / 70% SOH |
Scope of delivery
From design to commissioning
We deliver the full package: configuration selection, documentation, equipment, grid connection and O&M service.
Process
Grid Connection
Application, connection terms, connection agreement — timelines for LV, MV and HV.
Process
Building Permit
The 300 kWh threshold, local zoning plan (MPZP), environmental decision.
Process
Fire Safety
Gas detection, approvals with the State Fire Service (PSP), fire zones.
Process
Financing and Grants
NFOŚiGW (national environmental fund) programs, project finance, bankability requirements.
Process
O&M Service
LTSA, capacity test, availability and response times.
Track record
Volume delivered
412 MWh
total volume delivered
38
20 ft containers in operation
9
grid-scale projects above 10 MWh
| Project | Configuration | Application | Year |
|---|---|---|---|
| 4.8 MW PV farm, Wielkopolska region | 2.5 MW / 10 MWh | PV output shifting | 2025 |
| Manufacturing plant, Silesia region | 1 MW / 2 MWh | Peak shaving | 2025 |
| Grid-scale project, Mazovia region | 10 MW / 20 MWh | Capacity market | 2024 |
| EV charging hub, Lower Silesia region | 0.5 MW / 1 MWh | Connection power buffer | 2024 |
FAQ for investors
Request a quote — pricing in 48 h
Send us the project scale in MWh, the site location and the available grid capacity. We reply with a configuration, CAPEX range and delivery schedule.